Power

The amount of air required to operate the system ranges from 16-20 cu. ft./min at 120 psi. depending on the size of the vessel. This may be obtained from and existing compressor on the vessel. If however, this is not sufficient, and additional compressor should be installed. The compressor may be motor driven, belt driven or directly coupled to the main engine. Various types of compressors are available to suit the various installations.



Description of the GG System

The system compromises the following items:
    1) Air tank
    2) Filter/regulator/lubricator unit
    3) Control unit
    4) Fins and driving mechanism
    5) Bridge control
1) Air Tank

The air tank act as an expansion tank to even out the load on the compressor in spite of the fluctuation in the demand of the system. The tank is fitted with the following items :

    a- Drain cock
    b- ON/OFF remote valve
    c- Pressure gauge
    d- Air lnlet fitting

2) Filter/Regulator/Lubricator Unit

The unit consist of a microaelescer filter with automatic water ejector and a micro-fog oil lubricator. The lubricator injects oil in the stream of air in the form of a mist of microscopic oil droplets. This ensures that all internal parts and operating mechanism are adequately lubricated. The unit also has a pressure regulator to govern the air pressure going through the system.