The installation of the system ls very simple and normally
takes about 3-4 days for the complete installation and sea
trial.
Procedure for the installation of:
1- Air tank
2- Filter/lubricator/regulator unit
3- Control unit
4- Fin unit
5- Bridge control
6- compressor
7- Heat exchanger
8- Air dryer
9- Inter connecting tubing end fittings
1-Air Tank
The air tank is best installed over head. In this case the
tank is bolted to a wooden platform and the assembly ls then
installed over head any where ( mostly in the engine room ).
2-Filter/Lubricator/Regulator Unit
Install the filter/lubricator/regulator on any vertical
partition or bulkhead. one clearance below the bottom of the
unit must be at least 8" to allow disassembly. The unit
should be located in an easily accessible position to check
the oil level and top at as required.
3-Control Unit
Install the control unit on a transverse bulkhead or
partition so that the unit is facing either forward or aft.
the position of the control unit should be selected as close
as possible to the vessel center line so that the length of
the tubing running to the fin units are short and almost of
the same length. Also it should be as high as possible.
6
1
2
3
4
5
6
7
8
9
10
11
|