7-Heat Exchanger

The heat exchangers are installed in line with the raw water system of the main engines. The heat exchangers should be installed as close as possible to the compressors to minimize the length of the hoses running between the compressors and the heat exchangers, thus exposed to high temperature.

8-Air Dryer

The air dryer is installed on any vertical partition or bulkhead. The drainage from the dryer ( 1" line ) runs into the engine's muffler or generator's muffler.

9-Interconnecting Tubing & Fitting
a-Bridge Valve

    - Use 1/4'' nylon tubing from gauge to the distribution block of control unit ( 2 lines )
    - Use 1/4 tubing valve inlet ( in port ) to air tank.
    - Use 1/4 tubing from valve outlet ( out port ) to remote Valve on tank
b-Air Tank
    - Use 1/2" nylon tubing from the remote control valve to the filter/lubricator/regulator inlet.
    - Use 1/4" nylon tubing from the remote control valve to the bridge control. ( ON/OFF switch outlet ).
    - Use 1/4" nylon tubing from the air receiver to the bridge control. ( ON/OFF switch inlet ).
    - Use 1/4" nylon tubing from the air receiver to the governor on the compressor ( port marked RES ).

c-Filter/Lubricator/Regulator

    - Use 1/2" nylon line from the unit outlet to the control unit inlet.
    - Use 1/2" nylon line from the unit inlet to the air tank.

d-Control Unit

    - Use 1/4" nylon tubing from the control unit to the gauges on the bridge control.
    - Use 3/8" nylon tubing from the control unit to the fin unit. Use the color code on the driving    mechanisms, with red on forward slots.

e-Compressor

    - Use flexible high temperature hose from compressor air discharge to the heat exchanger.
    - Use 1/2" water heater hose from the compressor water cooling inlet to the raw water cooling on    heat exchanger.
    - Use 1/2" water heater hose from the compressor water cooling outlet ( top port ) to the raw    water cooling system on the heat exchanger.
    - Use 1/4" oil line hose from the compressor lubrication inlet to the engine lubrication system. This is    mostly taken from the engine oil sensor block.
    - Use 1/4" nylon tubing from the governor to:
      1- The second compressor ( from port market UNL ).
      2- The air dryer ( from port market UNL ).
      3- The air tank ( from port market RES ). Leave port market EXH open.

f-Heat Exchanger

    - Use 1/2" nylon tubing from the heat exchanger outlet to the air dryer.

g-Air Dryer

    - Use 1/2" nylon tubing from the dryer to the air receiver.