Interconnecting Tubing & Fitting

Looking For Interconnecting Tubing & Fitting at Gyro-Gale Stabilizers

A. Bridge Valve

  • – Use 1/4in polyurethane tubing from gauge to the distribution block of control unit (2 lines).
  • – Use 1/4in tubing valve inlet (in port) to air tank.
  • – Use 1/4in tubing from valve outlet (out port) to remote valve on tank.

B. Air Tank

  • – Use 1/2in polyurethane tubing from the remote control valve to the filter/lubricator inlet.
  • – Use 1/4in polyurethane tubing from the remote control valve to the bridge control (ON/OFF switch outlet).
  • – Use 1/4in polyurethane tubing from the air receiver to the bridge control (ON/OFF switch inlet).
  • – Use 1/4in polyurethane tubing from the air receiver to the governor on the compressor (port marked RES).

C. Filter/Lubricator Unit

  • – Use 1/2in polyurethane line from the unit outlet to the control unit inlet.
  • – Use 1/2in polyurethane line from the unit inlet to the air tank.

D. Control Unit

  • – Use 1/4in polyurethane tubing from the control unit to the gauges on the bridge control.
  • – Use 3/8in polyurethane tubing from the control unit to the fin unit. Use the color code on the driving mechanisms with red on forward slots.

E. Compressor

  • – Use flexible high temperature hose from compressor air discharge to the heat exchanger
  • – Use 1/2in water heater hose from the compressor water cooling inlet to the raw water cooling on heat exchanger.
  • – Use 1/2in water heater hose from the compressor water cooling outlet (top port) to the raw water cooling system on the heat exchanger.
  • – Use 1/4in oil line hose from the compressor lubrication inlet to the engine lubrication system. This is mostly taken from the engine’s oil sensor block.
  • – Use 1/4in polyurethane tubing from the governor to:
    • a. The second compressor (from port marked UNL).
    • b. The air dryer (from port marked UNL).
    • c. The air tank (from port marked RES). Leave port market EXH open.

F. Heat Exchanger

  • – Use 1/2″ polyurethane tubing from the heat exchanger outlet to the air dryer.

G. Air Dryer

  • – Use 1/2″ polyurethane tubing from the dryer to the air receiver.